Rock wool roof sandwich panels

Rock Wool Roof Sandwich Panels for Fire-Rated and High-Temperature Industrial Roofing

We manufacture rock wool roof sandwich panels with a non-combustible mineral fiber core (80–200 kg/m³) for projects where roof fire resistance, acoustic performance and high-temperature stability are the controlling specifications. With a melting point above 1000°C and Euroclass A1 achievable, rock wool roof panels are specified for industrial workshops with hot processes, chemical plants, public buildings and any structure where the roof must act as a fire barrier. Factory-direct from Shandong to Chile, Peru, Colombia and Indonesia.

LIAOHE rock wool roof sandwich panel on industrial building

Why Rock Wool Roof Panels from LIAOHE

Rock wool (mineral wool) is fundamentally different from foam-core roof panels. The core is made from basalt rock melted at ~1500°C and spun into fibers. It does not burn, does not produce toxic smoke, and maintains structural integrity at temperatures that would destroy PU, PIR or EPS cores. For roofs over welding bays, foundries, chemical storage, public assembly halls or any building where fire insurance is a major cost driver, rock wool changes the risk calculation.

We laminate the mineral fiber core between corrugated steel sheets in a continuous press line. The result is a rigid roof panel that delivers fire resistance, sound reduction (Rw ~30 dB) and thermal insulation in one product. At 80–200 kg/m³, these panels are 2–3× heavier than PU roof panels — this affects purlin sizing, lifting equipment and container load planning, all of which we handle as part of the quotation.

  • Core material: non-combustible mineral fiber (rock wool)
  • Product position: roof panel system (3-rib / 5-rib profile)
  • Factory-direct manufacturing, Shandong
  • Export packing and container-loading support
Rock wool roof panels in continuous lamination at LIAOHE factory

Technical Specifications

Final production data must follow confirmed drawings and project specifications. Rock wool roof panels are heavier and require careful structural coordination.

ItemTypical / Available RangeQuotation Note
Core materialNon-combustible mineral fiber (rock wool), basalt-basedConfirm required density and fire rating class.
Panel typeRoof panel (3-rib or 5-rib corrugated profile, overlap joint)5-rib recommended for fire-rated roofs; profile improves stiffness at longer spans.
Core density80–200 kg/m³; 100–120 kg/m³ standard for roof panelsHigher density improves fire resistance, sound reduction and span capacity.
Panel thickness50 / 75 / 100 / 120 / 150 mmSelected by fire resistance period (EI), span, and insulation target.
Thermal conductivity λ0.040–0.045 W/m·KHigher than PU/PIR; insulation thickness must be calculated per project U-value target.
Fire performanceA1 or A2-s1,d0 (EN 13501-1) depending on facing and adhesiveRock wool core is non-combustible; final classification depends on full assembly.
Span capacity (single-span)1.2–2.5 m typical at standard loadsLower than PU at same thickness due to higher self-weight. Span table per project.
Minimum roof slope5° (8.7%) recommendedSame installation practice as PU/PIR roof panels.
Effective width1000 mm standardCovers 1000 mm per panel after side-lap overlap.
Steel facing0.5–0.8 mm; top sheet PPGI/Galvalume, bottom sheet PPGI/Al-ZnThicker steel recommended due to higher panel weight during lifting and installation.

Fire resistance periods (EI 30/60/90/120) are project-specific and must be confirmed with the full roof assembly. Rock wool roof panels are 2–3× heavier than PU/PIR — purlin sizing, crane capacity and container weight limits must be verified per order.

Applications

Rock wool roof panels are specified where fire safety at the roof plane is the primary decision driver or where insurance/regulatory requirements mandate non-combustible roof construction.

  • Industrial workshops with hot processes — welding bays, foundries, heat treatment areas; see our Guatemala 9,560 m² project
  • Chemical and petrochemical storage roofs — fire compartment roofs where non-combustible materials are mandatory
  • Public assembly and commercial building roofs — where local building codes require non-combustible roof envelope
  • Acoustic-sensitive roof applications — generator rooms, compressor halls, manufacturing floors with high ambient noise

Manufacturing, Quality, and Delivery

Rock wool roof panel production requires specialized handling due to core weight, fiber orientation, and the need to maintain lamella integrity during lamination.

Rock wool roof panel corrugated roll forming at LIAOHE

Production Line

Continuous lamination with rock wool lamella orientation for maximum compressive strength. Corrugated top sheet is roll-formed in-line before the foaming station. Density and thickness are monitored per batch.

Rock wool roof panels in heavy-duty export packing

Export Packing & Loading

Heavy-duty packing with reinforced edge protectors, double steel strapping and ISPM 15 pallets. Rock wool roof panels are 2–3× heavier than foam-core: a 40HQ container may carry fewer square meters — we calculate load plans and weight distribution per order.

ISO 9001 quality management certificate of Shandong LIAOHE New Material Co Ltd

Certifications & Documents

ISO 9001 certified. Fire test reports (EN 13501-1, GB 8624), material safety data sheets (MSDS), acoustic test reports and span tables provided with quotation.

LIAOHE rock wool roof panels installed in Guatemala industrial project

Project Reference

Our rock wool roof panels are installed in industrial and commercial buildings globally. View all project cases →

Delivery Capability

Factory capacity, lead time and container-loading data for export planning.

Monthly Production Capacity

Rock wool lamination runs are scheduled separately from foam-core lines; typical monthly output is lower per shift due to handling weight.

Typical Lead Time

Standard specifications: 15–20 days after deposit. Custom colors, special coatings or non-standard thicknesses: 25–35 days. We confirm a production slot and vessel plan before order acceptance.

Container Loading

Because rock wool is 2–3× heavier than foam cores, a 40HQ container typically loads 500–700 m² of roof panels.

What We Need for Your Quotation

Send the following with your roof layout drawings and we return a quotation with span table and packing plan within 2–3 working days.

  • Panel type (roof) and core material (rock wool)
  • Required fire resistance period (EI 30/60/90/120) and Euroclass
  • Rib profile: 3-rib or 5-rib
  • Panel thickness, core density, and U-value target
  • Purlin spacing, purlin section size, roof slope
  • Local wind/snow load standard
  • Steel facing: thickness, coating type, color (RAL code)
  • Panel length and total quantity or roof area (m²)
  • Destination country and delivery port
  • Accessories: ridge caps, flashings, fasteners, lap-joint sealant

Send Roof Specifications for Rock Wool Panel Quotation

Email your fire rating requirements and roof layout drawings. Our team reviews fire classification feasibility, span capacity with purlin sizing, product configuration and packing plan. Quotation typically within 2–3 working days.

Chat on WhatsApp